{"id":2195,"date":"2024-11-18T16:24:38","date_gmt":"2024-11-18T08:24:38","guid":{"rendered":"http:\/\/jracking.online\/using-standard-of-warehouse-storage-rack%ef%bc%881-of-4%ef%bc%89\/"},"modified":"2024-11-20T13:52:49","modified_gmt":"2024-11-20T05:52:49","slug":"using-standard-of-warehouse-storage-rack%ef%bc%881-of-4%ef%bc%89","status":"publish","type":"post","link":"https:\/\/jracking.online\/fr\/using-standard-of-warehouse-storage-rack%ef%bc%881-of-4%ef%bc%89\/","title":{"rendered":"Utilisation de la norme de l'entrep\u00f4t de stockage Rack\uff081 Of 4\uff09"},"content":{"rendered":"<p><span style=\"font-family:Calibri;font-size:14px\">Exigences g\u00e9n\u00e9rales<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">1<\/span><span style=\"font-family:\u5b8b\u4f53;font-size:14px\">.<\/span><span style=\"font-family:Calibri;font-size:14px\">&nbsp;Non<\/span><span style=\"font-family:\u5b8b\u4f53;font-size:14px\">t<\/span><span style=\"font-family:Calibri;font-size:14px\">&nbsp;les supports de stockage doivent \u00eatre utilis\u00e9s sans acceptation.<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">2. La proc\u00e9dure d'exploitation ne doit pas d\u00e9passer les conditions d'exploitation maximales sp\u00e9cifi\u00e9es par le fournisseur, et les donn\u00e9es suivantes relatives \u00e0 la charge de travail de s\u00e9curit\u00e9 fournies par le fournisseur doivent \u00eatre respect\u00e9es :<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">A) La capacit\u00e9 de charge du plancher suspendu.<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">B) La charge uniforme maximale de s\u00e9curit\u00e9 de chaque compartiment.<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">C) Charge de s\u00e9curit\u00e9 maximale par m\u00e8tre de longueur de rack.<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">D) La charge maximale du bras de s\u00e9curit\u00e9 et du rack et la position du centre de gravit\u00e9.<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">E) Charge maximale de l'unit\u00e9 de s\u00e9curit\u00e9.<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">En cas d'utilisation d'un chariot \u00e9l\u00e9vateur ou d'un autre \u00e9quipement m\u00e9canique, les conditions d'utilisation sont les suivantes :<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">A) S'assurer que la qualit\u00e9 et le type d'outils de stockage sont compatibles avec les supports de stockage.<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">B) Les op\u00e9rateurs de chariots \u00e9l\u00e9vateurs et les autres op\u00e9rateurs doivent recevoir une formation et des conseils suffisants avant de commencer \u00e0 travailler.<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">C) Des panneaux d'information sur la charge doivent \u00eatre plac\u00e9s autour des rayonnages de stockage pour guider les caristes et les autres op\u00e9rateurs.<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">D) Le poids de la cargaison unitaire ne doit pas \u00eatre sup\u00e9rieur \u00e0 la charge nominale sp\u00e9cifi\u00e9e dans la conception de l'\u00e9tag\u00e8re de stockage.<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">E) La taille globale de la cargaison unitaire ne doit pas \u00eatre sup\u00e9rieure aux dimensions pr\u00e9vues pour la disposition et la structure des rayonnages de stockage.<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">F) Les chariots \u00e9l\u00e9vateurs \u00e0 fourche op\u00e9rant sur des rayonnages d'entrep\u00f4t doivent avoir une rigidit\u00e9 suffisante pour toute la hauteur d'extension et le poids de levage.<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">G) La largeur de l'angle droit des voies de circulation des chariots \u00e9l\u00e9vateurs ne doit pas \u00eatre sup\u00e9rieure au rayon de conception de la disposition des rayonnages.<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">H) S'assurer qu'il n'y a pas d'obstacle dans le canal d'op\u00e9ration ou dans la zone du chariot \u00e9l\u00e9vateur.<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">I) Les conducteurs de chariots \u00e9l\u00e9vateurs ou autres op\u00e9rateurs doivent signaler imm\u00e9diatement \u00e0 leur responsable tout accident ou dommage caus\u00e9 aux rayonnages de stockage.<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">Jracking est sp\u00e9cialis\u00e9 dans la production de divers rayonnages \u00e0 palettes, rayonnages cantilever, syst\u00e8mes de stockage mobiles \u00e9lectriques, mezzanines et plates-formes, syst\u00e8mes de stockage automatique de wagons-navettes, rayonnages push back, rayonnages \u00e0 grande port\u00e9e, rayonnages \u00e0 rivets, rayonnages drive in, rayonnages \u00e0 flux de cartons, rayonnages \u00e0 empilage et autres \u00e9quipements de stockage connexes.<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">&nbsp;<\/span><\/p>\n<p><span style=\"font-family:Calibri;font-size:14px\">Jracking applique strictement les normes ISO9001, FEM10.2.02, SEMA et AS4084-1993 dans toutes ses op\u00e9rations. Jracking offre une large gamme de produits pour r\u00e9pondre \u00e0 tous vos besoins en mati\u00e8re de traitement des commandes et de manutention : Palettiers Teardrop, palettiers Dexion, palettiers europ\u00e9ens et autres \u00e9quipements de travail. Que vous souhaitiez \u00e9quiper un entrep\u00f4t entier ou que vous ayez besoin d'une seule pi\u00e8ce d'\u00e9quipement, Jracking a une solution pour vous.<\/span><\/p>\n<p><a href=\"http:\/\/www.jracking.com\" target=\"_self\" rel=\"noopener nofollow\">www.jracking.com<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>General requirements &nbsp; 1.&nbsp;Not&nbsp;storage racks should be used without acceptance. &nbsp; 2. The operating procedure shall not exceed the maximum operating conditions specified by the supplier, and the following safety working load data provided by the supplier shall be executed: &nbsp; A) The carrying capacity of the suspended floor. &nbsp; B) The maximum safe uniform [&hellip;]<\/p>","protected":false},"author":1,"featured_media":2215,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[74],"tags":[],"class_list":["post-2195","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"acf":[],"_links":{"self":[{"href":"https:\/\/jracking.online\/fr\/wp-json\/wp\/v2\/posts\/2195","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jracking.online\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/jracking.online\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/jracking.online\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jracking.online\/fr\/wp-json\/wp\/v2\/comments?post=2195"}],"version-history":[{"count":0,"href":"https:\/\/jracking.online\/fr\/wp-json\/wp\/v2\/posts\/2195\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jracking.online\/fr\/wp-json\/wp\/v2\/media\/2215"}],"wp:attachment":[{"href":"https:\/\/jracking.online\/fr\/wp-json\/wp\/v2\/media?parent=2195"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/jracking.online\/fr\/wp-json\/wp\/v2\/categories?post=2195"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/jracking.online\/fr\/wp-json\/wp\/v2\/tags?post=2195"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}